Scoresby is a quiet, family-oriented suburb with a mix of 1970s–90s homes and newer developments, spread along Stud Road, Ferntree Gully Road, and the residential streets surrounding Scoresby Secondary College and Scoresby Village Shopping Centre.
Many homes here were built from the 1970s through to the 1990s, fitted with Bonaire, Breezair, Brivis, or Braemar evaporative systems that have been running reliably for decades. A common fault I encounter in November — at the start of summer — is water continuously running into the cooler tray even when the system is switched off. The culprit is usually a solenoid coil that has burnt out and failed in the open position
📞 Call or SMS now! 0420 982 770 : Same-day service where possible.
. Mon–Fri 10am–6pm | Sat 11am _ 3pm
. We’re just 20 to 30 minutes from Scoresby.
✅ Why Scoresby Locals Choose Fix2QIK
- Licensed & insured specialists since 2001 — we find root-cause-problem and repair it so the issue stays fixed.
- A true technician handles the job — not a call-centre plumber.
- Same-day local response in Scoresby and surrounds.
- Up-front quotes, no hidden fees, genuine parts.
- Fix Electronic faults on-site: control modules, wiring, sensors, PCB boards.
- We support major cooling brands: Brivis, Breezair, Braemar, Coolair, Bonaire & more.
Contact us on 0420 982 770. We’ve built our reputation on experience, quality and friendly works since 2001.
🔧 Local Issues We Repair in Scoresby
Soft Water, But Solenoid Coils Still Fail
Scoresby receives Silvan reservoir water, which is softer than Cardinia supply and gentler on valves and pumps. However, solenoid coil failure is an electrical issue rather than water-related. Coils degrade from heat exposure, voltage fluctuations, and age. The combination of hot roof space temperatures and years of electrical cycling weakens the coil winding until it eventually burns out — often failing in the open position where water cannot be shut off.
Original Solenoid Valves Reaching End of Life
Streets like Caribbean Drive, Dorado Street, and the residential pockets near Scoresby Primary School feature homes with evaporative systems that are 30–40 years old. Original solenoid valves have been opening and closing thousands of times over decades. The electromagnetic coil that controls valve operation eventually overheats from internal resistance, melting insulation and causing an open-circuit failure or a stuck-open condition.
November Continuous Water Flow
Every November, my phone lights up with Scoresby homeowners reporting water running continuously into the cooler — even when the system is off or unplugged. It’s predictable: the coil that should close the valve has burnt out over previous seasons. When water pressure is present, the valve has no electromagnetic force to hold it closed. Water flows freely until the mains supply is manually isolated.
Problem Clusters
I frequently attend homes near Stud Road, Ferntree Gully Road, and the streets around Scoresby Village where this burnt coil issue repeats. These areas have similar-age housing with original solenoid valves. When one home reports continuous water flow in early November, neighbours with similar-vintage systems often discover the same burnt solenoid condition within weeks.
📍 Book Now📞 Call or SMS 0420 982 770
There’s no extra fee if we need to return a second time to finish the job.
All prices are outlined in the written quote, including parts and labour, before the job begins.
🧰 Common Faults We Repair
- Pump not running or noisy.
- Float/level or solenoid valve stuck or leaking.
- Fan motor won’t start, capacitor fails or belt/pulley worn.
- Control module or wall controller unresponsive.
- Low airflow, warm output or duct leaks.
- Water leaks from roof pan or distribution system.
- Smelly, burn, damaged filter pads, ceiling ducts and vents.
Most repairs take 90–120 minutes, we have the fully stocked service van to complete most jobs on the first visit.
🛠️ Our Diagnostic & Repair Process
- Safe isolation and full system diagnosis.
- Electrical tests: motors, capacitors, wiring, sensors.
- Water system inspection: pump, float, valves, distribution.
- Run-test the system: airflow, temperature drop, noise, leaks.
- Clear repair plan & quote before any work begins.
- Post-work inspection, photos on request, warranty on labour & parts.
There’s no extra fee if I need to return a second time to finish the job.
🛠️ Specialist Skills — Control Module & PCB Repairs
I check voltages and signals at critical points in the control circuit — including the solenoid coil, valve-control relay, and the water level sensor that triggers fill cycles. I clear debris, resolder weakened connections, and rejuvenate terminals to prevent arc-over on 240-volt circuits. This is licensed electrical work, and unqualified technicians risk damaging your system and creating safety hazards in your home.
If an electronic PCB, control module, or solenoid driver circuit related to the continuous water flow fault requires full replacement — especially where the burnt coil has caused relay contact damage in the control board — I take the component to my workshop for renewal and return to your home in Scoresby (with no additional revisit travel fee) to reinstall and test it.

💬 Frequently Asked Questions
✔️ How much does a repair cost?
Most repair jobs fall within a defined range depending on fault and unit age. We charge a diagnostic fee, then quote clear repair costs upfront before proceeding.
✔️ Can you repair every brand and age of system?
Yes — we service modern and older roof-mounted evaporative coolers from major brands. If parts aren’t available or it’s not cost-effective, we’ll advise you honestly.
✔️ Is it safe to keep using a faulty evaporative cooler?
Not always. Issues such as water leaks, electrical faults or poor airflow can escalate into bigger problems. We prioritise safety and compliance, and will advice you appropriately.
✔️ Why is water continuously running into my cooler even when it’s turned off?
The solenoid valve coil has likely burnt out and failed in the open position. The coil that should close the valve when the system shuts down no longer functions, so water keeps flowing into the tray continuously until you manually shut off the water supply.
✔️ Can a burnt out solenoid coil be repaired or does the whole valve need replacing?
Usually just the coil needs replacing, not the entire valve body. However, if the valve has also suffered damage from overheating or debris, full replacement may be more practical. I test the coil and valve function to determine the best repair approach.
👍Qualifications & Your Peace of Mind
- Registered business – ABN: 40010599400. Trading since 2001. Fully Insured
- Fix2QIK is a team of licenced professionals:
- L084241 (RAC01 _ Refrigeration Mechanic)
- D15929 (Class 1 _ Fault Finding Electrician)
- A24341 (Advanced Electronic Technician)
- 115197 (VBA Plumbing Contractors)
- 110960 (VBA Plumbing Subcontractor)
- And other formally recognised qualifications in the HVAC-R Industry.
- We issue relevant compliant certificates.
- All subcontractors directly involved in your job are appropriately insured.
- Clear Quote, Affordable, Quick Repairs, Honest advice.
📍 Book Now — Local Cooling Repairs in Scoresby
📞 Call or SMS 0420 982 770
✔️ We fix evaporative coolers throughout Scoresby — including homes around Stud Road, Ferntree Gully Road and Caribbean Drive.
✔️ We also cover Same day Repairs in: Knoxfield, Wantirna South, Rowville, Ferntree Gully and Wheelers Hill.
__
Related links:
🔗 Evaporative Cooling Service: Scoresby.
🔗 Return to our Evaporative Cooling Repairs ->
✅ David Pham | Trading as Fix2QIK
❄️ Every summer, I’m out across Scoresby and nearby suburbs. I frequently replace burnt out solenoid coils causing continuous water flow in homes around Stud Road and Ferntree Gully Road — a common issue in older systems where decades of electrical cycling and heat exposure have degraded the coil winding until it fails in the open position, allowing water to run continuously. The burnt coil often causes secondary damage to the valve-control relay and PCB driver circuit from the coil’s short-circuit moment — faults I diagnose and rectify as part of the complete repair.
-> Brands I am experienced with: Bonaire | Braemar | Brivis | Celair | Breezair | Coolair
📞 More questions? Please Call my office: 0420 982 770

Office:0420 982 770
Based in Endeavour Hills
Mon–Fri 10am–6pm
Saturday 11am–3pm
–
Please leave a message
if I am unable to pick up;
I answer SMS Promptly!
| Wall Controllers | Evap-Cooler: Roof unit |
|---|---|
![]() | ![]() |
| Modules / Electricals | Mechanical |
|---|---|
![]() | ![]() |
📞 More questions? Call 0420 982 770