Express Brivis repairs solving your problems honestly: Fix all Faults and Errors.
Comprehensive Brivis Parts & Fan Motor Diagnostics.

. Introduction:
Advanced Brivis Evaporative Cooler Faults & Motor Troubleshooting in Melbourne.
Fix2Qik’s specialised service for Brivis Evaporative Cooler and Brivis motor troubleshooting in Melbourne, where we leverage the advanced capabilities of the Brivis Part Checker.
We are offering Quick, Precise, Honest troubleshooting & Diagnostic Services on Brivis systems.
📞 Call the experts today: 0420 982 770
Our experienced team providing clear quotes before works.
We Service all Brivis Cooling Models: Some listed in table -> Models list here
Repairing all Faults of Brivis Evaporative Coolers -> Faults & Errors list here.

Professional Service with Cutting-Edge Tool:
- Since 2001, Fix2Qik has refined the Enhanced-Brivis-Part-Checker.
- This tool enables live testing to identify serviceable parts.
- It empowers customers to make informed decisions.
Our Brivis-Part-Checker ensures Fix2QIK technicians stand out as true professionals, providing precise troubleshooting in Melbourne that surpasses competitors’ estimates.


Common Causes of Brivis Cooler’s Faults:
The faults are from various issues, but over 90% is commonly stem from the electronic connected parts and circuits, mostly including:
- Speed sensor faults,
- Control module errors,
- Power supply variations,
- Mechanical obstructions
- Loose connections,
- Faulty capacitors.
- Lack of qualified services.
- Lack of Seasonal maintenance.
Fix2QIK’s can assure your system performance and longevity. Call us!
Understanding Brivis Cooler’s Faults and Error Codes #60 and #65:
Error 65 indicates a motor recovering from a lockout due to overheating, while Error 60 suggests an open circuit in the motor’s internal winding or connections. These issues and many other faults in Brivis Cooling System underscore the need for expert intervention.
Fix2QIK’s specialised approach utilising the unique Brivis Part Checker guaranty quickly resolves the problems.
This innovative tool sets us apart from traditional diagnostic methods, such as multimeters, especially in identifying elusive issues like short windings in motors.

Past Brivis Cooling Repairs Demo:
Video 1 Description:
Watch how traditional methods diagnose Brivis motors during servicing. This video demonstrates the inaccuracy and limited usefulness of conventional diagnostic processes. Notice the impracticality of conducting these tests on rooftops or ladders, especially with the risk of water entering the storage sump and the danger of applying live electrical current for testing. Correctly determine the problem quickly is crucial in reducing the cost of repairs or servicing a Brivis Evaporative Cooler.
Video 2 Description:
Brivis Part Checker: Best Service tool for Brivis Evaporative Cooling Maintenances.
Discover the innovation of Fix2QIK with the custom-designed Brivis-Part-Checker. This video showcases how this unique tool revolutionises the troubleshooting of Brivis Coolers and Heater motors. Witness its superiority over traditional methods in terms of speed, safety, and cost–effectiveness, making it a game-changer in the field. The current supplying to the Faulty fan motor is turned down preventing electrical cable damages at the same time allow detailed inspection on the fault.
Video 3 Description:
Brivis Part Checker in action: Checking each individual components on a new Contour Brivis Cooler after its Water Pump spotted faulty. This is a Brivis’s warranty service. The L56 in this video has just been installed 1 day at a resident in Narre Warren VIC.
Video 4 Description:
Summary Brivis Part Checker function and application. This video is posted on social media. Brivis Evaporative Cooler not working and the advanced troubleshooting method of the Fix2QIK’s Brivis Part Checker.
Fix2QIK’s Benefits You the most.
- Superior Accuracy: Brivis-Part-Checker identifies faults reliably, unaffected by temperature variations that hinder multimeters, crucial for errors like motor lockout error 65 and open circuit fault error 60.
- Advanced Technology: Designed to surpass traditional tools, it provides consistent results aligned with Brivis’s standards.
- Live Testing Function: Enables real-time testing of all components, ensuring comprehensive diagnostics across various Brivis models.
- Efficient Diagnostics: Streamlines the troubleshooting process, making it quick and accurate for all technicians.
- Transparent Repairs: Offers precise, honest diagnostics, leading to clear, trustworthy service and quotes.
Fix2Qik’s Brivis-Part-Checker: The definitive tool for efficient and reliable Brivis Cooler Servicing in Melbourne.

Choose Fix2QIK for Brivis Faults & Fan Motor Services:
- Expertise in Brivis Systems: Ensuring top-notch service and repairs.
- Advanced Diagnostics: Brivis – Parts – Checker for efficient troubleshooting.
- Experienced Technicians: Local, Licenced, Insured, Experienced.
- Customer Focus: Prioritise your needs, responsive service.
- Clear Pricing: No hidden costs, just fair affordable pricing.
Onsite Precision Diagnostics Services for Brivis Systems:
- Water inlet solenoid valve,
- Water pump,
- Drain valve
- Damper assembly,
- Fan Motor,
- Control module,
- Electronics Circuit,
- Sensors & Switches.
- Onsite Brivis Cooling Service: Part testing & licensed DOA
warranty claims, if any, for Tradies. (*)T&C: please call..
Workshop’s testing for HVAC-R Businesses:
(Posted and Courier shipping items only, Sorry! no walk-in service)
- $6 each (ten fan speed sensors at a time). Repair: $30 /each sensor.
- $30 Motor testing fee (five motors at a time). No Rewinding or New Motor sales.
- $50 Control module testing fee (minimum 3 modules).
. We Service, refurbish and repair all Electronic Control Module and PCB for Brivis heating and cooling models, including obsolete models.
(Prices subject to change. 12 months warranty. Shipping costs non refundable. Please call for more info).
Please note:
. There is no over-counter-service at the trading address of Fix2QIK.
. Workshop’s Electronic Service is strictly for posted items from HVAC&R trade businesses only.
📞 Call us: 0420 982 770 | Melbourne’s leading Brivis Repairs Services.
Don’t let Brivis Cooling issues disrupt your comfort.
Let our experienced technicians guarantee your system’s optimal performance at reasonable price.

About Fix2QIK:
- Local, Trusted since 2001.
- On-Site Mobile Eftpos for Cards
- Approved parts with Warranty.
- Clear Quotation. All Jobs Guaranteed.
- Fully stocked for most models.
- Properly Insured & Registered.
Fix2QIK Trusty & Reliability: Known for our prompt and dependable service in Melbourne, suburbs near South eastern areas. We are Specialised HVAC-R Licenced Electricians.
The Fact is Over 90% Brivis Faults are connected to electronic and electrical systems NOT Plumbing. Fix2QIk is fully insured for these works.
Save time and money with Fix2QIK’s Advanced Testing:
Choose Fix2Qik for your Brivis Cooler service and repairs in Melbourne. With our Brivis Part Checker, we offer not just a repair service but a promise of accuracy, honesty, and professionalism. Whether it’s a Brivis motor fault or routine maintenance, and more. Fix2Qik is your trusted partner for all Brivis Cooling and Heating needs.
Appendices:
Table 1: Brivis Cooling (and Heating) Models we service near Melbourne. (back to top)
1. Brivis Models Affected by the faulty Motor: (not all listed, please consult your part supplier). Evaporative Coolers: AC60 to 65 | AD14 to 86 | CC24 to 45 | AD56-bal to 66D-bal | Advance F13 to F86 | Profiler P23 to P64 | Promina P24 to P76 | Contour L10 to L76 | Advance Plus F26 to F86 | Kaden Classic KC17 to KC32 | Kaden Low Pro KL16 to 28 | RINNAI A series 50 to 70. Ducted Gas Heaters: AUTO EMS20 to 26 | Buffalo BX5 / BX6 series | Compact Plus CMS21 | MPS He20 to He30 | MPS Me20 to Me35 | StarPro SP / B / MAX / PLUS series | | 2. Brivis Control Modules Affected by the Faulty Motor: ( not all listed, ask your supplier for part identifications) Evaporative Coolers: This sensor is commonly attached to control modules Brivis NE1, N-E3 / N-E5 / N-E6, Brivis TEK321 and is prevalent in Brivis heaters with variable speed motors.. Ducted gas heaters: NG2 / NG2-A / NG2-A+ | NG3 | MPS Low module | and more.. |
Table 2: Common Brivis Heater and Cooler error faults we offer same day service near Melbourne. (back to top)
Brivis Ducted Gas Heater Error Codes and Remedies: 1. Error code 40, 41, 42 and 43: . Fault: These errors indicated an overheat condition has occurred. Note that the the fan motor will operate at maximum speed. . Corrective actions: Check duct system. 2. Error code 46, 47 and 55 . Fault: Heater has failed to ignite within the specified time. System fault, call for repairs. 3. Error code 50 (most likely this caused due to lack of regular preventative maintenances) . Fault: Heater has locked out after four ignition attempts. This error can be cleared by using the reset button to restart the heater, however, the unless the condition has been rectified, the error is likely to occur again. . Corrective actions: Electronics gas control circuits, or Gas supplying components. Check other gas appliances for burners to verify the gas supplying to the heater is the only part that is currently not working. 4. Error Code 53 . Fault: Heater has locked out due to multiple overheat occurrences. . Corrective actions: Check the return air grille. 5. Error code 56 . Fault: A lockout has occurred on the pressure switch, usually caused by too much restriction on the flue pipe, or condensate drain (SP6 models). . Corrective actions: Check the flue pipe for blockages. Check the condensate piping for blockages (SP6 models). . | Common Brivis Evaporative Cooler Fault Codes: 1. Fault #30: FAN_LIMP: . No fan signal or incorrectly feedback. 2. Fault #40: . Water (low) sensing failed: Faulty sensor. Faulty Electronics control circuit. 3. Fault #41: . Water (high) sensing failed: Faulty sensor. Faulty Electronics control circuit. 4. Fault #42: . Not Draining: Drain pipe blocked. Faulty ServoSeal (or Damper and Snorkel Drain valve assembly). 5. Fault #50: . No Water detected: Water not supplying or inoperative Water inlet Solenoid / Valve assembly. 6. Fault #60 MOTOR OC: . Fan motor open-circuit, possibly winding open ciruit or electronic detection circuit is faulty. Wrong connection. 7. Fault #65 MOTOR LOCKOUT: . In conjunction with error code #30: fan limp fault is registered and a motor open circuit occurs. . An overheat cool down is initiated the motor lockout fault is flagged. . |
3. Testing motor and ohm values taken on the VOM and DMM
In Video 1: Digital Multimeter: Fluke 711, tests set on Ohm’s Auto Range. and hand-drawn Brivis’s Diagram as seen in video clip 1.



Results will vary on different meter’s brands and even between the two GOOD (working) Brivis Motors. The measurements above are true with that meters at 27C only.

. Melbourne Heating and Cooling Service expert!
Call or SMS: 0420 982 770
Contact Fix2QIK for Brivis Cooling Repairs and Services.
Breezair . Coolair . Braemar . Brivis . Celair . Bonaire . CoolBreeze .

Our works at Fix2QIK ensure your system run efficiently year-round, We have the services adapt to your requirements such as:
. Evaporative Cooling Solutions
. Ducted Cooler services
. Cooling Maintenances.
. Repairs
. Replaces
. Electronics module & PCBs servicing.
( we have these services have been listing since 2001 in the old website -> here <- )
For any further information or clarification on our terms and conditions, please contact us.