Celair Evaporative Cooling Repairs in Melbourne.

Onsite Celair Cooling Repairs with Cost-Effective Solutions.

Fix2QIK in Melbourne is your perfect choice for repairing Celair Evaporative Coolers.

Experienced and professional, we offer precise diagnostics to provide solution to your Celair Evaporative Cooler Air Conditioner: At the component level.

We equipped to repair all issues including the Electronic board (PCB), Control Box or Control Modules, Water Pump, Motors, Fan, Pads, Water Inlet Solenoid, Wall Controller, and numerous other Celair Cooling parts. We know all the facts about Evaporative Air Conditioner Repairing. We have a workshop specialised in refurbishing the Evaporative Cooler parts.

No guesswork: Each component is individually quality testing and check to confirm defective prior to its replacement or refurbishing on-site, with written warranty and a very competitive price.

Call a Celair repair today!
0420 982 770

🔧 Some Celair Evaporative Cooler Repairing Costs :

  • EAC2003, EAC2008, EAC2009, TEK632, Control Board: $380 *
  • Water Pump: $120 *
  • Float Valve: $85 *
  • Drain Sum Dump: $135 *
  • Water Solenoid Valve: $60 *
  • Capacitor: $45
  • Pressure tube: $30
  • Cooling Pad Repair: $30 each + parts
  • Fitting Blower Motor: $220 each + parts
  • Modification from EAC2003 EAC2008 EAC2009 to TEK7EC (New kit: Control box, wall controller & wire loom): $220 each kit+ parts.
  • Seasonal general cleaning, motor lubrication and pcb adjustment: $180.
  • Wall controller Replace: $80 -> $120 + parts.
  • Workshop’s complex pcb / parts testing: $75 (prepaid & non-refundable but is deducted from the repair cost)

  • ——-T & C ———-
    * Indicates refurbished parts swapped and fitted on-site at customers, on single storey premises, with 24 months warranty.
    * Servicing areas approximately 25km distance from Endeavour Hills.
    * Price excludes one time call-out fee which is covering: Travel, toll, parking for job assessment, problem cause diagnostic & fault finding.

    * Prices are subject to change per market value, please ask during job booking, prices varies without prior notice from suppliers . . ESV compliant certificate incurs extra fee. . Freights are prepaid by customers and not refundable . . Allows up to 2 days for job report on freighted-in items . . Uncollected items are disposed after 3 months since the date of notification via sms to customer and impossible to recover afterward.

    . Workshop’s testing and refurbishing items MUST be Pre Booked, we DO NOT take walk in un-arranged work and will turn you away no matter what, sorry!

    | please contact us for more information |
    ———————–
celair-evaporative-cooler-logo

Affordable Evaporative Cooler Repairs in Melbourne, since 2001.

celair-evaporative-cooler-exposed-internal-part-fan-anf-weather-seal

Why Trust Fix2QIK?

  • Certified, insured business
  • Fixed price upfront quote
  • Consistent work ethic
  • Genuine or approved parts
  • Written warranty
  • Onsite Eftpos payment
  • AM 500: Classic with metal grills cover outside the cooling pads.
  • Profile 500 series: 600 Watts motor. Air Output 9326 m³/hr.
  • Profile 600 series: 750 Watts motor. Air Output 11810 m³/hr.
  • Profile 750 series: 750 Watts motor. Air Output 13810 m³/hr.
  • Profile 850 series: 750 Watts motor. Air Output 15968 m³/hr.
  • Profile 750: 475 Watts motor.
  • Profile 900: 600 Watts motor.
  • Profile 1105: 750 Watts motor.
celair-charcoal-evaporative-cooler-installed-on-a-tiled-roof

Common Celair Cooling Issues We Address:

celair-ducted-cooling-air-conditioner-system-installed-in-a-tinroof-house
  • Motor and Fan issues: Overheating, slow or can’t change speed
  • Pump Matters: Malfunctions, failures, leaks
  • Controller & Remote: Display glitches, delayed responses
  • Unpleasant Odours: Off or burning smells from outlets
  • Water Troubles: Leaks, overflows, residue deposits
  • Water inlet solenoid valve faults
  • Structural Hitches: Noisy machines, shattered vents, feeble airflow
  • Fuse and RCD/Safety switch problems

Common Celair Cooler Symptoms Requiring Our Repairs in Melbourne

  • Won’t turn on, no power, trip RCD, blows fuse,
  • Switched on ok at controller but no air flow,
  • Controller has no display, dimmed, flashing,
  • Remote, controller shows error code, not responding,
  • Musty smelly from air vents when the fan working,
  • Burning smell coming from ceiling vents,
  • Water trickling on the roof,
  • Sound of water keep running in the gutters,
  • Fan motor blows warm air, no cooling,
  • Not cooling with water leaks until turned off.
  • Switched on but no cold air coming from vents,
  • Fan runs only low speed, can not be adjusted,
  • Fan motor can only run at highest speed,
  • Motor noisy, Strange noise when use, mechanical noise,
  • Broken vents, Ceiling diffuser broken
  • Zoning control not working, weak air blows at a Zone
  • Duct component, damper stay shut or stuck open,
  • Filter, water pads on the cooler are broken, and more ,
  • Lack of cleaning and sanitising.

Specialised electronic servicing for Celair coolers in Melbourne, VIC:

. Control Box, Control Module and PCB: (almost 90% of all Celair’s faults is connected to these parts).

. Fix2QIK offers reliable repairs for Control Modules, PCBs, and Part Restorations, especially on Celair Ducted Evaporative Coolers Air conditioner. This service is available Australia-wide and to overseas customers.

* Points set Fix2QIK apart from the competitors:

  • Fix2QIK excels in repairs and holds unique air conditioning certifications & licences essential for Celair Evaporative Cooler repairs.
  • We prioritise safety with proper tests and certificates, which is often overlooked by competitors.
  • Appropriately ensure comprehensive insurance coverage, encompassing electronic works and providing peace of mind.
  • Transparent about repair costs, presenting them upfront. Our detailed technical assessment post-service empowers owners to manage future servicing expenses.

Fix2QIK: The Ultimate Answer for Celair Repairs

Ageing Celair systems (10-20 years) usually have repairable defects. We offer solutions at a fraction of a new system’s cost, and always provide upfront written quotes.

bonaire-evaporative-cooler-replaced-new-water-pads-internal-view

Your Steps with a Celair Cooler Malfunction:

1. Diagnose the issue: Often related to electronics and electromechanical parts.
 
2. Your Options:

a. Replace the entire system based on multiple quotations.
b. Leverage Fix2QIK's expertise for the swift solutions at a fair affordable price.
c. Contact the manufacturer and potentially wait without a guaranteed repair.
d. Reach out to local contractors, risking inadequate training and potential overcharging.

. All Celair evaporative coolers have CPUs and electronic circuits. These technologies are too difficult and often out-of-scope for an average tradesperson who would inevitably suggest a new cooler's replacement. Before that, call us for a thorough inspection. The problem sometimes is just simply a faulty component on the electronic circuitry, or cooler's electrical that can be rectified as cheaply as a fraction of the costs compared to replacing a whole new system.

. Fix2QIK refurbishing and repairing service: Will bring your cooler back to life, extending serviceable condition into future. This is costing much less compared to the new installs and still has warranty to perform correctly.

We find 90% of Celair Cooling’s problems of not working are directly connected to the electronic circuits
.
Only Fix2QIK is Specialising Equipped to Rectify This Type of Faults On-Site.
.
No One Else fits this particular category.
Don’t risk calling a wrong tradie!

evaporative-cooling-service-electronics-workbench

Our proficient extends to many other evaporative cooling brands

evaporative-cooler-brands-bonaire-braemar-breezair-celair-coolbreeze-coolair

. Braemar. Bonaire.
. Brivis. Breezair.
.Celair. Coolair.
. CoolBreeze.

Superior Evaporative Cooling Services in Melbourne

Fix2Qik has over 20 years of experienced in servicing Celair ducted evaporative coolers that intergrade electronic circuits. Whether it’s a simple service or whole system replacement; We’ve got you covered!

circuit-boards-inside-of-the-electronic-control-modules-boxes-in-evaporative-coolers-melbourne

. Your comfy home await!

Celair Cooling Repairs in Melbourne Dial: 0420 982 770

Fix2QIK: Solving Evaporative cooling problems.

Heating Cooling Air Conditioning Service | Melbourne, Victoria, Australia.

Ducted Evaporative Cooling Brands We Handle:

Breezair . Coolair . Braemar . Brivis . Celair . Bonaire . CoolBreeze .

fix2QIK-QR-code-with-business-logo

Service Areas: We offer on-site evaporative cooling services to Melbourne’s areas and suburbs approximately 25km distance from Endeavour Hills, VIC 3802.

fix2QIk-heating-cooling-service-melbourne

We have the services adapt to your requirements such as:
. Evaporative Cooling Solutions
. Evaporative cooling services
. Cooling System System Maintenances.
. Repairs
. Replaces
. Electronics module and PCBs servicing.

Fix2QIK’s old version of this webpage which still can be viewed here -> [ old page ]


Appendices

Fault / Problem
(.)
Diagnostic / Check
()
Description
1. Unit fails to start,. Black – out,
. Tripped Circuit Breaker,
. Blown Fuse,
. Electrical supply abnormal,
. Wait until Power restored,
. Reset (Follow instruction),
. Replace Fuse ( same type),
. Call Service Centre,
2. Pump Fail to start,. Mechanical problem, seized,
. Pump burnt out,
. Call service centre,
. Call service centre,
3. Water leaks: Overflow. Float valve faulty,
. Water distribution parts faulty,
. Excess drain at Cooling Pads,
. Replace Float valve,
. Adjusts or Replace part(s),
. Pads problem, call service,
4. Water Droplet in air-stream. Delivery tubes problems,
. Excess pump volume,
. High humid days,
. Service call,
. Service call,
. Fan or Auto Mode only,
5. Humidity, Wet, Damp floor,. Inadequate venting or Exhaust,
. Ambient humidity high,
. Open more: Windows, doors,
. Open wider: Exhaust stale air,
. Turn water Pump off,
6. Inadequate Cooling,. Dirty filter pads,
. Dried cooling pads,
. Water distribution problem,
. Service call,
. Service call,
. Adjust Water distribution; Service call,
7. Unpleasant Odour. Unit located near odorous source,
. Cooling pads old,
. Cooling pads new,
. Leaves or debris
. Remove source,
. Replace pads,
. Using for over a week,
. Service call,
8. White streaks, White formation on cooling pads,High content mineral water supplied, . Service call,
. Call installer,
. New water connection,
A user guide to decipher Common problems for Celair evaporative coolers.
. Motor Issues:
Fan motor doesn’t start or shows intermittent pulsating.
Fan speed uncontrolled, stuck at full speed mode.
Motor noisy with unusual mechanical noise.
Motor overheats and stops on overload.
Motor starts and stops at intervals.

. Pump Problems:
Pump doesn’t run or is noisy and dead stuck.
Pump ejects water even when turned off.
Pump fails to operate.
Pump runs but does not circulate water or pads lack water.

. Controller and Remote Issues:
No screen display or error codes; buttons not working.
Delayed or frozen commands; touch screen and touch pads unresponsive.
Cooler will not run / Wall control displays fault.

. Water Issues:
Water trickling on the roof.
Water running in gutters even when turned off.
Leaks from cooler, dripping on the roof.
Continuous overflow of water.
Water being thrown into the area being cooled.
Formation of white deposits in tank and on pads.
Continually leaking water when turned off.
. Odour and Smell:
Unusual odour from the duct and vents.
Musty smell when the fan is working.
Burning smell from ceiling vents.
Unpleasant odour.

. Electrical Problems:
No power; trips RCD; blows fuses and circuit breakers.
Electrical, electronics, and mechanical faults in solenoids, valves, control modules, and circuit boards.


. Air Flow Problems:
No air flow when switched on.
Fan runs at low speed only, or at the highest speed only.
Fan blows warm air with no cooling.
Inadequate cooling.
Cooler turns ON and OFF repeatedly.


. Structural and Component Failures:
Broken vents and ceiling diffusers.
Belt slipping or wearing excessively.
Noisy unit or air conditioner
Zoning control failures; weak air flow in zoning vents.
Stuck or shut dampers; broken filters and water pads.
A comprehensive breakdown of common issues Fix2Qik has experience in, but there’re more to come.
celair-evaporative-cooler-am-500
Celair evaporative cooler: AM 500, cleaning
celair-cooler-controller-tek425-variable-speed
Celair cooler: Tek425 Controller, repaired
celair-profile-500-serviced-in-melbourne
Celair evaporative cooler: Profile 500 repaired & serviced,
celair-profile-850-serviced-narre-warren-melbourne
Celair evaporative cooler: Profile 850, serviced
celair-cooler-control-box-tek-632-tek-600-series
Celair Control: Tek 632 Control Box repairs,
Celair evaporative cooler: Profile 750 troubleshooting,
celair-600-maintenance-melbourne-internal-view
Celair cooler: profile 600, maintenance
celair-controller-tek-622-4-button-wall-controller
Celair Control: Tek 622, 4 buttons repaired
celair-profile-600-750-repaired-melbourne-internal-view
Celair cooler: Profile 750, repaired

. Terms and Conditions of service apply. Please contact for details.

. Disclaimer: Brand names and trademarks belong to their respective owners and are used here for descriptive purposes only.