Breezair Cooling Servicing suburbs near Parkmore Keysborough.
Melbourne’s Best on Breezair Evaporative Cooling Services to most Suburbs near Parkmore Keysborough and close-by areas.
Fix2QIK: Top solution for all Breezair evaporative cooling requirements near Parkmore Keysborough.
All Jobs Written Warranty; Honest Upfront Quotes; Onsite Mobile Eftpos for Cards.
🔧 Maintenance, Diagnostic & Replacements.
📆 Seasonal Services.
📍 Local Presence: Swift on-site works in Parkmore Keysborough Vic 3173.

Breezair Cooling & Heating Services.

Why Choose Fix2QIK?
We handle all Breezair Evaporative Cooling Services.
- Specialised Expertise: 20+ years in the field. All jobs warranty. Compliant certificates supplying.
- Advanced Technical Skills: Exceptional electronic skill and HVAC-R knowledge.
- Prioritising your safety and trust: Fix2QIK’s business is properly Registered and appropriately Insured.
Breezair Models We Service:
We cater to all Breezair models available in Australia. Some include:
- BM, BMQ Series,
- CPQ, CPL, CPS series,
- EA, EX, EXH, EXQ, EXS, EXV, EXVQ, EXT series,
- LCQ, LCQI, LCS, LPQI, LCB series,
- RPA400 to 1500 series,
- TBA, TBQ, TBQI, TBS, TBSI Series,
- ES105, ES125, ES145, ES165, and,
- EV215, EZ215, EZH215 series.
Refer to photos at the end to identify your model.
Breezair Evaporative Cooling Services in Parkmore Keysborough, VIC.
Services:
. Schedule Servicing for your Breezair Cooling system, from Seasonal Servicing to Factory Designated General Maintaining, and more..
. Electronics Servicing: Keep your cooler in top shape, ensure safety and reduce energy usage: By including our unique Electronics Circuits Preventative Servicing, which includes Electrical Safety Testing to the main electrical connection board.
Diagnostic & Replacements:
. If your Breezair Evaporative Cooling system is defective and beyond repairs or at the end of serviceable lifespan, our trusted Plumber is standing-by for your urgent installation, (and we hope this could save you time from sifting unregulated results online)!
. Written warranty and all Compliant certificates will be supplied for your peace of mind.
Common Breezair Cooler Symptoms Require Our Services

- Won’t turn on, no power, trip RCD, blows fuse,
- Switched on ok at controller but no air flow,
- Controller has no display, dimmed, flashing,
- Remote, controller shows error code, not responding,
- Musty smelly from air vents when the fan working,
- Burning smell coming from ceiling vents,
- Water trickling on the roof,
- Sound of water keep running in the gutters,
- Fan motor blows warm air, no cooling,
- Switched on but no cold air coming from vents,
- Fan runs only low speed, can not be adjusted,
- Fan motor can only run at highest speed,
- Motor noisy, Strange noise when use, mechanical noise,
- Broken vents, Ceiling diffuser broken
- Zoning control not working, weak air blows at a Zone
- Duct component, damper stay shut or stuck open,
- Filter, water pads on the cooler are broken, and more ,
- Lack of cleaning and sanitising.
- Above are just some common problems found on recent services, there are more to come,
Our proficient also extends to other evaporative cooling brands, such as: Braemar, Brivis, Bonaire, Celair, CoolBreeze and Coolair.
Appendix C: Showcase Fix2QIK’s in-depth understanding of common Breezair evaporative cooling issues and proven adeptness at servicing them.
Decoding Error Codes
We possess an in-depth understanding of Breezair evaporative cooling error codes, ensuring prompt solutions. Some codes:
- 01: Communication failure.
- 02: No water detected.
- 03: EEPROM failure.
- and more, from error 04 to 08 fault codes.
Our technicians are trained for servicing these issues!
Appendix B: Featuring Guide to Breezair Error Codes.

Beyond Standard Servicing with Fix2QIK
- Custom Tools: Allows quick servicing and maintenances, thus saving times and your money.
- Unmatched Skillset: Specialised in Breezair cooling with advanced servicing expertise.

Best price and workmanship
Quotes jobs upfront on-the-spot
20+ Years field work experience
Approved parts with warranty
Mobile Eftpos, accept cards onsite
Superior Evaporative Cooling Services in Parkmore Keysborough
fix2QIK:
Has custom–engineered testing equipment specially made for Breezair-specific service and adjustment.
Has electronic lab to rejuvenate Breezair evaporative cooling parts, control module and circuit boards.
Has Workshop for Breezair motor & mechanical part’s restoration.
Fix2QIK is the onsite field experts in servicing Breezair ducted evaporative coolers that intergrade electronic circuits. Whether it’s a simple service or whole system replacement; We’ve got you covered!

Reach Out Today!
Your comfy home awaits!

Fix2QIK provides Breezair Evaporative cooling services near Melbourne’s southeastern suburbs within 25km from Endeavour Hills, post code 3802.
Appendices
Appendix B: Breezair Evaporative Cooling Fault Codes
Error Code (On controller) | Diagnostic LED Flashes (Red DIAG led) | Description |
---|---|---|
01 | 1 pulse repeatedly | Communication failure. |
02 | 2 pulses repeatedly | No water detected, or water probe failure. |
03 | 3 pulses repeatedly | EEPROM failure (new electronic control box replacement needed). |
04 | 4 pulses repeatedly | Water remains, no drain or drainage parts faulty. |
07 | 7 pulses repeatedly | Main power supply frequency is biased 8% approximately out of range. |
08 | 8 pulses repeatedly | Recovered from a short-term power supply fault. Power surge recovery mode activated successfully. |
Appendix C: Common Breezair Cooling Faults Encountered and Serviced
. Motor Issues: Fan motor doesn’t start or shows intermittent pulsating. Fan speed uncontrolled, stuck at full speed mode. Motor noisy with unusual mechanical noise. Motor overheats and stops on overload. Motor starts and stops at intervals. . Pump Problems: Pump doesn’t run or is noisy and dead stuck. Pump ejects water even when turned off. Pump fails to operate. Pump runs but does not circulate water or pads lack water. . Controller and Remote Issues: No screen display or error codes; buttons not working. Delayed or frozen commands; touch screen and touch pads unresponsive. Cooler will not run and the wall control displays fault. . Water Issues: Water trickling on the roof. Water running in gutters even when turned off. Leaks from cooler, dripping on the roof. Continuous overflow of water. Water being thrown into the area being cooled. Formation of white deposits in tank and on pads. Continually leaking water when turned off. | . Odour and Smell: Unusual odour from the duct and vents. Musty smell when the fan is working. Burning smell from ceiling vents. Unpleasant odour. . Electrical Problems: No power; trips RCD; blows fuses and circuit breakers. Electrical, electronics, and mechanical faults in solenoids, valves, control modules, and circuit boards. . Air Flow Problems: No air flow when switched on. Fan runs at low speed only, or at the highest speed only. Fan blows warm air with no cooling. Inadequate cooling. Cooler turns ON and OFF repeatedly. . Structural and Component Failures: Broken vents and ceiling diffusers. Belt slipping or wearing excessively. Noisy unit or air conditioner Zoning control failures; weak air flow in zoning vents. Stuck or shut dampers; broken filters and water pads. . Common component serviced and replaced: Vents, Ceiling Diffusser, Control module, PCB, Wall controller, Thermostat, Zone Damper and Zoning system, Pump, Ductworks, Room fan, Motor, Speed sensor, Switch, Water Sensor, Mechanical Dropper, Drainage, Water tray, Electrical connections, Electronics, Wiring, Relay, Solenoid, Circuit boards, Display. |
Appendix A: Breezair Models in Parkmore Keysborough VIC. Serviced by Fix2QIK









Breezair Cooling Wall Controllers:








. Braemar. Bonaire.
. Brivis. Celair.
. CoolBreeze.
.Coolair .
- Terms and Conditions of service applied, please contact for details.
- Disclaimer: Brand names and trademarks are belong to their respective owners, and being used here for descriptive purposes only.